A-2

Publication 1771Ć6.5.116 - July 1996

Description

Value

Keying

between 10 and 12

between 24 and 26

Wiring Arm

Catalog Number 1771-WG

Field Wiring Arm Screw Torque

7Ć9 inchĆpounds

Agency Certification

(when product or packaging is marked)

CSA certified

CSA Class I, Division 2, Groups A, B, C, D certified

UL listed

CE marked for all applicable directives

Installation Instructions

1771Ć5.46

1

The inputs are protected to 35V.

2

Only 8 volts can be placed directly across the input when configured in the current mode.

3

Refer to publication 1770-4.1, "Programmable Controller Wiring and Grounding Guidelines for Noise Immunity."

Word 24 of the block transfer write data table shows the module scan
time for a given configuration. These figures are the time it takes to
sample all channels and process the data.

Table A.A

Scan Time in SingleĆEnded Mode

Numberof Oversamples

Word 24

Time (ms)

0

798

7.98

1

392

3.92

2

451

4.51

4

567

5.67

8

798

7.98

16

1260

12.60

32

2183

21.83

64

4028

40.28

128

7718

77.18

256

15100

151.00

Table A.B

Scan Time in Differential Mode

Numberof Oversamples

Word 24

Time (ms)

0

402

4.02

1

199

1.99

2

229

2.29

4

287

2.87

8

402

4.02

16

634

6.34

32

1096

10.96

64

2018

20.18

128

3864

38.64

256

7554

75.54

Module Scan Time