Technical Specifications

Table A.1 – Service Conditions

AC Line Distribution System Capacity

(maximum) for 460 VAC Units

1000KVA, three-phase with 30,000 amps symmetrical fault

current capacity with a line impedance of less than 5%. (85,000

amps fault current capacity with optional AC line reactors. See

table 5.1.)

Control Method

All-digital vector, sinusoidal pulse-width-modulated (PWM)

Displacement Power Factor

0.96

Line Frequency

50/60Hz (+2 Hz)

Line Voltage Variation

-10% to +10%

Line Dip Ride-Through

FVC: Maximum 500 milliseconds

V/Hz, SVC: Adjustable up to 999.9 seconds (See P.042)

Maximum Motor Lead Lengths

76 meters (250 feet) typical (refer to section 3.2.2.4)

Remote Operator Control Wire Length

Up to 303 meters (1000 feet) from the drive

Analog Speed Reference Resolution

1/1024 (10 bits) 0.1%

Acceleration Adjustment Range

0.1 to 999.9 seconds (within the ability of current)

Carrier Frequency

2 kHz, 4 kHz, or 8 kHz, software-selectable

Current Limit Adjustment

Vector: U.006 to 150% (based on motor nameplate rating)

V/Hz: 50% to 110% (based on drive nameplate rating)

Service Factor

1.0

Speed Adjustable Range

From 0 RPM to maximum speed (vector)

Speed Regulation

Vector: 0.01% FVC, 0.5% SVC (steady state)

V/Hz: Motor slip dependent

Speed Reference Resolution

1 RPM with local keypad, -4095 to +4095 counts with a network

or serial reference

Torque Control Response

180 to 220 Hz

Torque Linearity

+3% with optimal parameter setting (typical) (see parameter

U.005)