Wiring the Regulator Board Terminal Strip

7-1

C

HAPTER

7

Wiring the Regulator Board

Terminal Strip

This chapter describes how to wire the Regulator board terminal strip for stop,

encoder feedback, and remote control signals.

The signals available through the terminal strip are shown in tables 7.1 to 7.7 and

figures 7.1 and 7.2. Table 7.8 provides additional information.

Note that when the Control Source parameter (P.000) is set to remote (rE), the drive

will be controlled by the signals connected to the terminal strip. Refer to the

GV3000/SE Software Start-Up and Reference manual for more information on how

parameter P.000 is used to specify where the drive is controlled from.

Table 7.1 – RS-232 Connections (Terminals 1-3)

Terminal #

Signal

1

Transmit (Tx)

2

Receive (Rx)

3

Regulator Common

Notes: The RS-232 terminals should only be used when the RS-232 communication

port (J8) or an Operator Interface Module (OIM) is not being used, as all three devices

use the same transmit/receive lines.

Table 7.2 – Encoder Connections (Terminals 4-9)

Terminal #

Signal

4

+15 VDC

5

Phase A

6

Phase A Not

7

Phase B

8

Phase B Not

9

Regulator Common

Notes: An encoder feedback device must be installed if FVC regulation is used.