1-4

Installation/Wiring

(girder, joist), a floor ground rod, bus bar or building ground grid.
Grounding points must comply with national and local industrial safety
regulations and/or electrical codes.

Fuses

The DC SCR Precharge Module is designed for internal application inside
the drive(s) enclosure. The customer may install the external DC bus fuses
if the fuse protection does not exist inside the drive. National and local
industrial safety regulations and/or electrical codes may determine
additional requirements for these installations.

Minimum Capacitance

To operate and test the module, at least one drive must be connected at the
power terminals “+DCin” and “+DCout” to provide a minimum DC bus
capacitance (470 microfarads). One 7.5 kW (10 HP) PowerFlex

®

700H or

PowerFlex 700S drive provides the required minimum capacitance.

Important: If the drive (inverter) is disconnected from the DC bus, the DC

SCR Precharge Module internal fault detection circuit will not
interpret the condition as a “Precharge Not Completed” and
will not stop gating the SCR.

Maximum Loading

To avoid overloading the DC SCR Precharge Module, the following
requirements apply:

• The DC input current sum (Normal Duty rating at 50°C/122°F) of the

connected drive(s) must not exceed the continuous DC bus output
current rating of the DC SCR Precharge Module at 50°C/122°F.

• Multiple drives may be connected as long as the maximum current rating

is not exceeded.

For the DC input current values of the drives (PowerFlex 700H, PowerFlex
700S or 1336 PLUS

II), please refer to tables in Appendix A of their

respective User Manuals.

Table 1.A

shows examples for maximum loading of the DC SCR Precharge

Module when it is used for PowerFlex 700H or PowerFlex 700S drive
applications.

Table 1.A Maximum Loading when Used with PowerFlex 700H/700S Drive(s)

DC Input Rating of Connected Drive(s)

DC SCR Precharge Module Drive(s)

700H/700S
Frame Size

Normal Duty
Input DC Amps

Input DC
Voltage

Rated Cont.
DC Amps

Part Number

Normal Duty
Output AC Amps

Output
AC Volts

10

490A

650V

500A

370696

460A

460V

11

690A

650V

750A

370711

650A

460V

12

870A

650V

1000A

370715

820A

460V

13

1507A

650V

1600A

370707

1421A

460V