Installation environment, Driver installation environment – Rockwell Automation 1442 Eddy Current Probe System User Manual

Page 12

Advertising
background image

12

Rockwell Automation Publication ICM-UM004C-EN-E - February 2014

Chapter 1

Installation

Installation Environment

Driver Installation Environment

Install the driver in a location that satisfies the following environmental and
installation conditions.

Environmental Conditions

Install Conditions

If there are walls or other obstacles at the cable connection surface of the

driver, make sure to keep spacing as illustrated below. Take care not to bend
the cable excessively.

Feature Specification

Ambient temperature

Must be in a range of -30…80 °C (-22…176 °F) when devices are operating.

Ambient humidity

Must be in a range of 30…95% RH (noncondensing) when devices are operating.

Vibration condition

Must be 10 m/s

2

(1 g) or less at 10…150 Hz.

Air cleanliness

We recommend an air dust-particle amount of 0.2 mg/m

3

or less.

We recommend an especially low amount of corrosive gasses, such as hydrogen
sulfide, NOx gas, and chlorine, and conductive particles, such as iron dust and
carbon. The allowable amounts of hydrogen sulfide and NOx gas, based on JEIDA-
29 (1979) Class S1, are shown below.

JEIDA: Japanese Electronic Industry Development Association

JEIDA-29 (1979) CLASS S1
Hydrogen sulfide: 0.01 ppm or less, NOx gas: 0.05 ppm or less
(Ambient temperature: 25 °C ± 5 °C (77 °F ± 9 °F), humidity: 40…80%
RH)

60 mm (2.4 in.)

Advertising