Installation
Chapter 1
1442-PS-18xxE (18 mm English)
1442-PS-1820E0510A
88.2
900
780
1442-PS-25xxM (25 mm metric)
1442-PS-2505M0510A
176
1800
1557
1442-PS-25xxE (25 mm English)
1442-PS-2520E0510A
196
2000
1734
1442-PS-50xxM (50 mm metric)
1442-PS-5005M0010A
176
1800
1557
1442-PS-50xxE (50 mm English)
1442-PS-5020E0010A
196
2000
1734
1442-PR-08xxM (8 mm rev mnt metric)
1442-PR-0803M0505N
8.5
87
75.2
1442-PR-08xxE (8 mm rev mnt English)
1442-PR-0812E0205N
6.8
69
60.2
Table 2 - Torque Requirements
Sensor
Example
Tightening Torque
N•m
kgf-cm
lb•in
ATTENTION: Make sure to tighten the jam nut at the specified torque.
If tightened with excessive torque, the sensor can be damaged. If the
tightening torque is too small, it can come loose.