Example 4

If dimension X is less than 1.2 times the tip diameter, the
measurement will be affected by the attachment plate.

Example 5

If dimension Y is less than 3 times the tip diameter, the
measurement will be affected by the attachment plate.

Example 6

If the attachment plate around the sensor top is
chamfered, it will be affected by the attachment plate.

Example 7

If the target and the sensor top are not parallel
(dimension X1 and X2 are not the same), it will affect the
reading.

Example 8

If dimension X is less than the minimum linear range from
sensor tip specification for the sensor, the measurement
will not be accurate

.

Table 1 - Installation Examples