Antelope Audio Eclipse 384 User Manual

Page 28

Advertising
background image

Follow Monitor: The Eclipse 384 syncs to the digital input that feeds the current monitor being

used. (Note that if you choose an analog input or the A/D, the Eclipse 384 will be automatically

locked to the system clock.

Follow Digital Out: The Eclipse 384 syncs to the selected source that feeds the De-Jittered digital

outputs.

2. Clock A/B Sample-rate:

Set the sampling rate used by the corresponding clock (A or B). Sample rates can go up to 384kHz.

3. Varispeed:

You can adjust varispeed up/down to 12,256% or -+ 200 cents.

4. -/+ Options:

Options of -+ 4% or -+0,1%

5. Sampling Rate Display:

Displays the current sample rate used by the corresponding clock

6. Atomic Indicator:

When this light is lit, the device is receiving timing reference from an Atomic Clock (Such as the

Antelope 10M).

7. Oven Indicator:

When lit, this indicates that the device is the master clock.

8. Lock Indicator:

When lit, this shows that the device is locked to a signal.

9. WC Outputs:

You can select which clock will be fed on which individual WC output. Note that in single clock mode

(factory setting), you cannot adjust this option and Clock A clocks all the outputs.

2

29