Changing the boresight (pan) on a single smartbeam, Antenna – CommScope ATC200-LITE-USB User Manual

Page 101

Advertising
background image

Bulletin 639536 • Revision L

October

2014

15-1

Section 15

Changing the Boresight (Pan) on a Single
SmartBeam

TM

Antenna

The boresight (pan) may be adjusted on any device that is addressed, configured, and whose current
state does not prevent antenna movement. Examples where movement is prevented include devices
that are not responding to commands from the program, devices that are in the middle of a move or
configuration change, and devices that are experiencing a mechanical malfunction.

1. Switch to RET Device view by selecting ‘Show RETs’ from the drop down list below the Device

Information list.

2. From

the

Device Information list, click on the device ending in a ‘p’ to be moved (Figure 15-1).

3. Click

Move Selected at the bottom of the screen (Figure 15-1).

Figure 15-1. Selecting Device for Boresight (Pan) Adjustment.

1. Click on individual device to select for Boresight
(Pan) change.

2. Click Move Selected.

Advertising