CommScope ATC200-LITE-USB User Manual

Page 54

Advertising
background image

Section 5–Actuator Protocol Mode Switching

ATC200-LITE-USB Teletilt

®

RET System

5-4

October

2014

Bulletin 639536 • Revision L

5.0.2 Switching a Single ATM200-002 to Ericsson Protocol

Note: This procedure may only be applied when a single RET is connected.

Connect the ATC200-LITE-USB controller to the PC with the serial cable.

1.

Always use the serial

cable with this system.

Note: When switching to/from Ericsson mode, using a USB connection is not possible.

To switch a single ATM200-002 to Ericsson proprietary protocol, select

2.

Tools

Switch Protocol

Mode

ATM3

Single ATM200-002: AISG to Ericsson. See Figure 5-4.

Figure 5-4. Switching To Ericsson Protocol.

3. After the actuator has been reset to Ericsson proprietary protocol, the ATC200-LITE-USB

controller software can no longer be used with the actuator. Only use Andrew EFCT software on

the PC that operates the controller (Figure 5-5).

Warning

Portions of the operational configuration stored on the RET can be lost when switching to /

from Ericsson mode. Because antenna model information will be lost, the antenna table

would have to be reprogrammed to return to the previous setting.

Advertising