CommScope ATC200-LITE-USB User Manual

Page 6

Advertising
background image

ATC200-LITE-USB Teletilt

®

RET System

iv

October

2014

Bulletin 639536 • Revision L

6. When removing or replacing ESDS equipment, hold the device or assembly through the electro-

static-free wrap, where possible. If this is not possible, lift the device or assembly by its body only.
Do not touch component leads, connector pins, or any other electrical connections or paths, even
though they are covered by conformal coating.

7. Do not allow ESDS equipment to come in contact with clothing or other ungrounded materials

that may have an electrostatic charge. Charges on non-conductive material are not equal. For
instance, a plastic storage bag may have a –10,000 volt potential 1/2 inch from a +15,000 volt
potential with many such charges all over the bag. Do not hand ESD equipment to another person
until it is safely packaged for protection for ESD.

8. When moving ESDS equipment, always touch the surface on which it rests with bare skin for at

least one second before lifting. Before setting it on any surface, touch the surface with your free
hand for at least one second. Contact with bare skin provides a safe discharge path for charges
accumulated while you are moving around.

9. While servicing equipment containing ESD devices, do not handle or touch materials such as

plastic, vinyl, synthetic textiles, polished wood, fiberglass, or similar items that can generate static
charges; unless you repeat the grounding process with bare hands after contacting these materi-
als.

10. Where possible, avoid repairs that require soldering at the equipment level. Soldering irons must

have heater/tips assemblies that are grounded to an electrical ground. Do not use standard plastic
solder suckers (special antistatic solder suckers are commercially available).

11. Ground the leads of test equipment momentarily before you energize the test equipment and

before you probe ESD devices or assemblies.

12. Work benches used for setting ESDS equipment should have ESD protective work surfaces.

These work benches should also have personnel ground straps. These straps prevent discharge of
static electricity from personnel handling ESDS items on the work bench surface. The work bench
surface should be connected to a ground through a ground cable. The resistance in the bench
top ground cable should be located at or near the point of contact with the top of the work bench.
The resistance should be high enough to limit any leakage current to 5 milliamperes or less. This
takes into consideration the highest voltage source within reach of grounded people and all the
parallel resistances to ground, such as wrist ground straps, table tops, and conductive flooring.

Advertising