CommScope ATC200-LITE-USB User Manual

Page 65

Advertising
background image

ATC200-LITE-USB Teletilt

®

RET System

Section 7–Changing the Electrical Downtilt-Single

Bulletin 639536 • Revision L

October

2014

7-2

4. The

Set Actuator Position screen will appear (Figure 7-2).

Note all parameters that can be configured are displayed on this screen. This information may
be used as a reference to help determine the new tilt setting. However, configuration items
cannot be changed from this screen. All changes to configuration items must be done with the
Configuration screen as discussed in Section 6.

5. Enter the new angle in the New Tilt text entry field to change the electrical downtilt. Note that

the allowed range of angle values is displayed in the Min Electrical Tilt and Max Electrical Tilt
fields in the top part of the screen. Any downtilt angle within this range may be entered. Downtilt
is controllable with a precision of 0.1 degree. Other axes may use whole degree precision
(Figure 7-2).

Examples: Five degrees downtilt may be entered as 5 or 5.0. A downtilt of five and one-half
degrees would be entered as 5.5.

6. Click

the

Activate button (Figure 7-2) to apply changes to the electrical downtilt for this an-

tenna. Alternately, to exit the screen without sending any changes, click on the Close button.
Antenna movement will begin after the Activate button is applied.

A progress indicator bar (located to the left of Current Tilt) will continually update for as long as
the move is in progress.

Figure 7-2. Configuring New Electrical Downtilt Setting.

1.

ngle

may

be entered with the precision of 0.1 degree (Ex: 5.0 or 5.5) .

Progress

Display.

Advertising