CommScope ATC200-LITE-USB User Manual

Page 104

Advertising
background image

Section 15–Changing the Boresight (Pan)-Single SmartBeam™

ATC200-LITE-USB Teletilt

®

RET System

15-4

October

2014

Bulletin 639536 • Revision L

8. At the successful completion of an antenna movement, the Current AZ/Pan field will update to

show the new pan azimuth and the New AZ/Pan text entry box will be cleared in preparation for
the next move (Figure 15-4). At this point, you may click on the Close button to exit this screen
and return to the main screen. Alternately, this process may be repeated to further adjust the bore-
sight (pan) or to reapply changes where movement had previously failed, such as a temporary
mechanical jam.

9. After closing the Set Actuator Position screen, the main screen will show the new boresight (pan)

setting in the Device Information list.

After all boresight (pan) adjustments are made and you are ready to end the program session, a
report can be saved to a file for future reference (see Section 18).

Advertising