8. hold burner at throat. Lift front of burner to

clear orifice. Burner which holds pilot can only

be removed by lifting the burner adjacent to its

right first.

Figure 30: Burner Cleaning and Installation

9. Brush top of burners with a soft bristle brush, see

Figure 30. Vacuum burners. Check orifices to see

that drilled passageways are free of lint or dirt.

10. vacuum tip of Pilot Burner.

B. CLEAN FIREBOx by vacuuming. Exercise care

not to disturb insulation inside the base.

C. INSTALL BURNERS by reversing procedure used

to remove burners. Make sure burner with pilot

assembly is in same location as original installation

- see Table 8.

Check burners to see that they are located properly

in slot at rear of burner tray, see Figure 30.

Reinstall injection shield assembly (40mm burners

only, where used) and burner access panel.

Reconnect flame roll-out switch wires, pilot gas

supply, thermocouple lead or pilot lead.

D. ChECK MAIN BURNER and PILOT FLAMES,

see procedure Section II Operating Instructions,

paragraphs 5 and 6.

5.

ChECK ALL CONTROL AND DAMPER

OPERATION ANNUALLY see procedure in Section II

Operating Instructions, paragraphs 7 through 10.

6.

REMOvAL OR REPLACEMENT OF PILOT

ASSEMBLY OR PILOT ASSEMBLY PARTS

If pilot assembly, thermocouple or pilot orifice need

replacing, remove main burner with pilot using

procedure described in paragraph 4.
A. To replace orifice:

1. Disconnect pilot tubing. The honeywell Q350

pilot orifices are insert type retained by the

compression fitting. The Honeywell Q327 and

Q348A pilot orifices are spud type screwed into

pilot burner. Replace with desired orifice. See

Key No. 5B.

2. Reconnect pilot tubing and check for leaks.

B. To replace honeywell Q309A thermocouple in

Q327 or Q350 pilot:
1. Loosen attachment nut securing thermocouple to

barrel of pilot burner. Disconnect other end at

combination gas valve.

2. Remove thermocouple and replace with equal.

C. To replace complete pilot assembly.

1. Remove machine screws holding pilot burner to

pilot bracket.

2. Disconnect pilot piping.
3. Disconnect all other leads to pilot.
4. Select pilot assembly with identical model

number, reconnect leads and pilot tubing -

resecure to pilot bracket.

D. To adjust or check spark gap between electrode and

hood on honeywell Q348A pilot.
1. Use round wire gauge to check spark gap.
2. Spark gap should be 1/8 inch for optimum

performance.

E. Reinstall main burner following procedure described

in paragraph 4.

7.

LUBRICATION

There are no parts requiring lubrication on the part of

the service technician or the User. Circulator bearings

are water lubricated.

Table : Pilot Burner Location

1" Burner

0mm Burner

Boiler

Model

Main Burner with

Pilot Bracket *

Pilot Burner Located

Between Main

Burners *

1 Inch

40mm

1 Inch

40mm

202

1

1

1 & 2

---

202X

1

1

1 & 2

1 & 2

203

1

1

1 & 2

1 & 2

204

2

2

2 & 3

2 & 3

205

3

2

3 & 4

2 & 3

206

4

3

4 & 5

3 & 4

207

6

3

6 & 7

3 & 4

208

7

4

7 & 8

4 & 5

209

8

4

8 & 9

4 & 5

210

9

5

9 & 10

5 & 6

* Main burners numbered left to right as viewed from