3.

Press the button immediately to the left of the rotary switch once.

4.

Drop the 6 quarters through the acceptor. The IDX will blink once after each coin.
Verify that the light (LED) blinks 5 times after the last coin is entered.

5.

Replace the rotary switch back to zero.

4. If you are accepting old $2 coins:

6.

Remove the front cover by pushing in and up at the bottom right corner of the
main body of the unit (near the phone number printed on the cover).

7.

Find the rotary-switch and set it to the position labeled number 3.

8.

Press the button immediately to the left of the rotary switch eight times.

9.

Drop the six different new style 2 dollar coins through the acceptor. The IDX will
blink once after each coin. Verify that the light (LED) blinks 5 times after the last
coin is entered.

10.

Replace the rotary switch back to zero.

5. If you are accepting new $2 coins:

1.

Remove the front cover by pushing in and up at the bottom right corner of the
main body of the unit (near the phone number printed on the cover).

2.

Find the rotary-switch and set it to the position labeled number 2.

3.

Press the button immediately to the left of the rotary switch eight times.

4.

Drop the six different new style 2 dollar coins through the acceptor. The IDX will
blink once after each coin. Verify that the light (LED) blinks 5 times after the last
coin is entered.

5.

Replace the rotary switch back to zero.

6. If you are accepting site-specific tokens:

See Token Setup above for more information.

1.

Find the rotary-switch and set it to the position labeled number 1, 2 or 3.

2.

Press the button immediately to the left of the rotary switch once (or more for a
different number of pulses).

3.

Drop the six sample tokens through the acceptor, and verify that the light (LED)
blinks multiple times after the last coin is entered.

4.

Reset the rotary switch to 0 and replace the front cover.

a) To program the IDX to accept two different types of tokens, token 1 for $1 and

token 2 for $2:

1.

Set the rotary switch to position 1

2.

Press the button to the immediate left once

3.

Drop the six sample tokens and note that the LED blinks multiple times after the
last token

4.

Set the rotary switch to position 2

5.

Press the button twice (for 2 pulses or $2)

Advertising