Placing a mark on an echosounder image, Measuring distance, Pausing the echosounder – B&G Zeus Touch 12 User Manual

Page 59: Recording the echosounder data

Advertising
background image

58 |

The echosounder |

Zeus Touch Operator Manual

Placing a mark on an echosounder image

You can position a mark at the vessel’s position by pressing and holding the MENU key.
You can position a mark on a selected echosounder item by tapping the screen and then
activating the menu.

¼

Note:

Only marks positioned by using the cursor will include depth information.

Measuring distance

The cursor can be used to measure the distance between the position of two observations on
the sounder image. It is easier to use the measure function when the sounder image is
paused.

1.

Activate the menu to start the measure function

-

The cursor will be positioned in the middle of
the panel, and the distance will be measured
from this position

2.

Tap on the screen to select the second measuring
point

-

A line will be drawn between the measuring
points, and the distance will be listed in the
Information window

When you press the

Finish measuring

panel button or the X key the echosounder will

resume to normal scrolling.

Pausing the echosounder

You can pause the sounder, allowing you to examine the sounder echoes. The function is
activated from “The echosounder settings panel”, see page 60.
This function is useful when you need to position a waypoint exactly on the echosounder
panel, and if you are using the cursor to measure a distance between 2 elements on the
image.

Recording the echosounder data

You can record echosounder data and save the file internally in the Zeus Touch unit, or on to a
Micro-SD card inserted into the unit’s card reader.
The function is activated from “The echosounder settings panel”, see page 60.

The following options are available:

Bytes per sounding

Select how many bytes per seconds that are to be
used when saving the log file. More bytes yield better
resolution, but will cause the record file to increase in
size compared to using lower byte settings.

Log all channels

Logs all available sonar data simultaneously.
When logging all channels, logs are saved in SL2
format instead of .slg format.

Log in XTF format

Optional logging format for SideScan data. This will only be available when a StructureScan
unit is connected.
This format does not log all channels into one file. The format is used for third part application
support on the PC (like SonarWiz) that need access to the StructureScan data.

Advertising
This manual is related to the following products: