Press ‘RESET/ENTER’ 5) Display shows "dP.ActV" Decimal Point Effect Selection menu.
Press ‘RESET/ENTER’ 6) Display flashes "yES" (default) as confirming that the decimal point position is active

otherwise "NO" as independent.

Press ‘▲/MAX

7) To scroll or select the desired effect for your setting.

Press ‘RESET/ENTER’ 8) Display shows "StOREd" stored message momentarily then advances to "Set dP"

Decimal Point Setting menu.

Press ‘RESET/ENTER’ 9) Display shows "FFFFFF" (default) no decimal point option or previous selection of

decimal point location.

Press ‘▲/MAX

10) Scroll through the 6 available selection as 000000, 00000.0, 0000.00, 000.000,
00.0000, and 0.00000 for the suitable choice to match your selected input range and type.

Press ‘RESET/ENTER’ 11) Display advances to "FILtER" Filter Configuration submenu. If a change was made, the

controller will also show "StOREd" stored message momentarily.

14.4 FILtER

Enter FILTER CONFIGURATION Submenu:

Press ‘RESET/ENTER

12) Display shows "CNt by" Counter by or round-off feature. (To enter, Press
RESET/ENTER’).

Press ‘MENU

13) Scroll through 3 available selections of Filter configuration: "CNt by", "FILt.tP" and
"FILt.tM". Refer to the flowchart below.


CNt by

Enter COUNT BY FILTER FUNCTION MENU:

Press ‘RESET/ENTER

14) Display flashes "001" (default) or previous setting value.

Press ‘▲/MAX

15) Scroll though 7 available selections: 001, 002, 005, 010, 020, 050 and 100 for your
choice of setting.

Press ‘RESET/ENTER

16) Display advances to "FILt.tP" Filter Type Selection Menu. If a change was made, the
controller will also show "StOREd" stored message momentarily.

FILt.tP

Enter FILTER TYPE SELECTION MENU:

Press ‘RESET/ENTER

17) Display flashes "A.b.C.F IL" Adaptive Bandwidth Control Filter.

Press ‘▲/MAX

18) Scroll through 2 supported types: "A.b.C.F IL" or "MOV.AVE" (Moving Average) for
your desired option.

Press ‘RESET/ENTER

19) Display advances to "FILt.tM" Filter Type Selection Menu. If a change was made, the
controller will also show the "StOREd" stored message momentarily.

FILt.Tm

Enter FILTER TIME SETTING MENU:

Press ‘RESET/ENTER

20) Display flashes "004" (default) or previous setting value.

Press ‘▲/MAX

21) Scroll though 8 available selections: 001, 002, 004, 008, 016, 032, 068 and 128 for
your choice of setting.

Press ‘RESET/ENTER

22) Display advances to "FLS.dSP" Flashing Display Setting Menu. If a change was made,
the controller will also show the "StOREd" stored message momentarily.