Detailed object list – Baumer GNAMG User Manual

Page 21

Advertising
background image

Manual_GNAMG_CANopen_EN.doc

21/41

Baumer IVO GmbH & Co. KG

21.11.12

Villingen-Schwenningen, Germany

3.4.2. Detailed object list

Object 1000

Device type

SubIndex

0

Data type

Unsigned 32

Access

ReadOnly

Default

0004019Ah

EEPROM

No

Meaning

Information ond device profile and device type

Parameters

0x019A = 410 = device profile inclination sensor
0x0004 = Two axis with resolution max. 32-bit

Object 1001

Error register

SubIndex

0

Data type

Unsigned 8

Access

ReadOnly

Default

0h

EEPROM

No

Meaning

Current error code

Parameters

Bit0 = Generic error
Bit4 = Communication erro

r (overrun, …)

Bit7 = Manufacturer- specific

Object 1003

Pre-defined error field

CiA (CAN in Automation) defines here about 200 different error codes. This documentation only describes the
sensor-relevant error codes.
This object saves the latest 8 errors or warnings that occurred.

SubIndex

0

Data type

Unsigned 8

Access

ReadWrite

Default

0

EEPROM

No

Meaning

Read: Number of errors or warnings
Write 0: error reset

Parameters

0..8


SubIndex

1..8

Data type

Unsigned 32

Access

ReadOnly

Default

0

EEPROM

No

Meaning

Errors or warnings occured, subindex 1 being the last, subindex 2 the second-
to-

last,…… entry

Parameters

Not yet defined

Object 1005

COB-ID SYNC Message

SubIndex

0

Data type

Unsigned 32

Access

ReadWrite

Default

80h

EEPROM

Yes

Meaning

Defines COB-ID of the synchronisation object (SYNC)

Parameters

Bit 31

not defined

Bit 30

1=Sensor generates SYNC messages, 0=no SYNC message generated

Bit 29

1=29 Bit SYNC COB-ID (CAN 2.0B), 0=28 Bit SYNC COB-ID (CAN 2.0A)

Bit 28..11 Bit 28..11 of 29 Bit SYNC COB-ID
Bit 10..0

Bit 10..0 of SYNC COB-ID

Advertising