4 error diagnostics (red led), 5 working counter, Error diagnostics (red led) – Baumer ATD User Manual

Page 23: Working counter, Able, 26 e, Rror, Tate, Tatus

Advertising
background image

EtherCAT

23/42

Baumer Thalheim GmbH & Co. KG

2011-10-04/rnik

Eschwege, Germany

3.2.2.4 Error diagnostics (RED LED)

Generic encoder errors or state transition errors are signalized to the user via ERROR State LED, supported
LED states are:

ERROR STATE

State description

OFF

No Error

Blinking

Invalid Configuration

Single Flash

Unsolicited state change

ON

Watchdog

Table 26 Error State Status

3.2.2.5 Working Counter

In 1-Buffer mode (please refer to 2.3.2.2) the master may check the working counter value. This value will be
incremented by +1 if the encoder internal application controller was able to successfully write process data
into the ECAT controller. This mechanism enables the master to detect encoder freezing in a PDO transmis-
sion synchronous manner.