6 dc timing, 1 consecutive sample point jitter, 2 shift time – Baumer ATD User Manual

Page 28: 3 calc and copy time, Dc timing, Onsecutive sample point jitter, Hift, Able, 31 c, Alc and

Advertising
background image

EtherCAT

28/42

Baumer Thalheim GmbH & Co. KG

2011-10-04/rnik

Eschwege, Germany

6 DC

Timing

The exact data sampling time while DC mode depends on the sum of the two parameters: 0x1C33:3 (= Shift
Time) and Tjs (Jitter on sampling time). The minimum cycle time depends on the setting of the Scaling Func-
tion Control bit.

The time the encoder needs (from the SYNC0 signal point) to be able to put process data into the DPRAM
can be estimated by adding the Shift Time and the Calc and Copy Time (Table 31 Calc and Copy Time).

6.1

Consecutive sample point jitter

For the system designer there one value of interest: the absolute jitter between two consecutive sampling
points (Jitter) J. This value includes all device systematic jitter sources. Please refer to Table 32.

6.2 Shift

Time

Shift time is defined to be the time the encoder needs to start sampling data. This time information plus the
absolute system time gives the time stamp of the actual sample value. This means the sampled position data
has a fix relationship to the DC clock of the network.

6.3

Calc and Copy Time

The time the slave controller need for calculate and copy the sampled data to the SM data buffer (e.g. into
Ethernet Frame) strongly depends on the SFC bit.

Calc and Copy Time [µs]

Device Name

Product
Code

Device
Type

SFC=0

SFC=1

9

SFC=1

10

ATD4 B ***Y*** 15/16EC 0x0001**** 0x0002 ****

26,4

29,8

41,0

ATD4 B ***Y*** 17/12EC 0x0001**** 0x0002 ****

41,8

41,9

42,0

ATD4 B ***Y*** 15EC

0x0001**** 0x0001

****

23,5

23,9

28,1

ATD4 B ***Y*** 17EC

0x0001**** 0x0001

****

33,7

33,8

36,8

ATD2 B ***Y*** 14/16EC 0x0002**** 0x0002 ****

28,6

30,8

40,4

ATD2 B ***Y*** 17/12EC 0x0002**** 0x0002 ****

42,8

42,9

43,0

ATD2 B ***Y*** 14EC

0x0002**** 0x0001

****

23,5

23,9

28,1

ATD2 B ***Y*** 17EC

0x0002**** 0x0001

****

34,7

34,8

37,8

Table 31 Calc and Copy Time

For a full information about relationship between shift time, calc and copy time, Ethernet Frame length and
SYNC0 generation please refer to LIT[05].

9

Value is given for Scaling Function Control enabled and default encoder resolution

10

Value is given for Scaling Function Control enabled and lowest encoder specific resolution value.

Advertising