3-6

I

NSTALLATION

Open the servo saw’s electrical
enclosure.

Turn the disconnect dial on

the door to the OFF or O position and
open the door.

Insert the main power wire

through the knockout

in the side of the enclosure. Secure the wire with a rubber
compression fitting or strain relief.

Connect the power wires

to the terminals indicated

on the wiring diagram that came with your machine.

Check every terminal screw

to make

sure wires are secure. Gently tug each
wire. If a wire is loose, use a screwdriver
to tighten the terminal.

Connect the ground
wire

to either grounding

point shown in the diagram.

1

2

IMPORTANT: Always refer to
the wiring diagrams that
came with your saw before
making electrical connec-
tions. The diagrams show the
minimum size main power
cable required for your saw,
and the most accurate electri-
cal component information.

C

ONNECTING

THE

M

AIN

P

OWER

S

OURCE

3

WARNING: Electrical hazard

Before performing any work on this product, dis-
connect and lock out electrical power sources
to prevent injury from unexpected energization
or start-up. A lockable device has been provid-
ed to isolate this product from potentially haz-
ardous electricity.

WARNING: Improper installation, oper-
ation, or servicing may result in
equipment damage or personal injury.

This equipment should only be installed, adjust-
ed, and serviced by qualified technical person-
nel who are familiar with the construction, oper-
ation, and potential hazards of this type of
machine.

All wiring, disconnects, and fuses should be
installed by qualified electrical technicians in
accordance with electrical codes in your region.
Always maintain a safe ground. Do not operate
the equipment at power levels other than what
is specified on the machine serial tag and data
plate.