Diagrams, Installation & operation manual, Figure 12-2 wiring diagram – Crestron electronic Crest Condensing Boiler 3.5 User Manual

Page 59: Continued)

Advertising
background image

59

Installation & Operation Manual

12

Diagrams

(continued)

Figure 12-2 Wiring Diagram

-T

-T

-T

-T

-T

-T

-T

-T

-T

2 3

1

1 2

4 5

3

2 3

1

1 2

4 5

3

M

1

2

3

Notes:
1. All wiring must be installed in accordance with: local, state, provincial and national code requirements per either N.E.C. in USA or C.S.A. in Canada.
2. If any original equipment wire as supplied with the appliance must be replaced, it must be replaced with wire having same wire gauge (AWG) and rated for a
minimum of 105°C. Exceptions: Replacement high vo ltage spark lead and ribbon cables must be purchased from the factory. Use of a non-approved spark lead
or ribbon cables can lead to operational problems which could result in non-repairable damage to the integrated controller or other components.
3. Actual connector block locations may vary from those shown on diagrams. Refer to actual components for proper connector block locations when using
diagrams to troubleshoot unit.

WIRING DIAGRAM

LBL20280 REV A

BOX DEPICTS

OPTIONAL ITEMS

BOX DEPICTS

DUAL SENSOR

SINGLE HOUSING

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

CN1-12

CN1-5

CN1-10

CN1-11

CN1-6

CN1-9

CN1-8

CN1-7

CN1-1

CN1-2

CN1-3

CN1-4

17

CN3-6

CN6-2

CN3-7

CN3-14

CN6-1

CN3-13

CN3-12

CN3-11

CN3-10

CN3-9

CN3-8

CN6-3

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

CN3-1

CN3-2

CN3-5

CN3-3

X3-2

X3-4

X6-1

X6-11

X3-1

X6-2

X6-14

X6-10

X6-13

X6-4

X3-3

X7-8

X7-7

X8-14

X8-13

X8-12

X8-11

X8-15

X8-5

X8-6

X8-16

X8-7
X8-17

X8-18

X8-1

ALARM

CONTACTS

RUN-TIME

CONTACTS

TANK

THERMOSTAT

LOUVER

PROVING

24 VAC LOUVER

RELAY COIL

AUX

SWITCH 1

AUX

SWITCH 2

SHIELD

SHIELD

A

B

MODBUS

OPTION

+

-

-

+

RATE

OUT

BOILER

PUMP OUT

SYSTEM RETURN

SENSOR

SYSTEM SUPPLY

SENSOR

0-10V

0-10V

TANK

SENSOR

OUTDOOR

SENSOR

+

+

-

-

0-10V

0-10V

BMS

IN

SYSTEM
PUMP IN

SHIELD

SHIELD

A

B

CASCADE

R

R

R

O

R

O

L

B

K

B

R

B

R

Y

R

O

HIGH LIMIT

SWITCH

R

R

X6-1

X6-2

X6-3

Y

G

R

R

P

MODBUS

BOARD

L

B

R

L

B

R

R

B

W

R

O

OR/W

P

W

L

B

K

B

J3-5

J3-4

J3-6

LWCO

BOARD

J3-3

J3-2

J2-1

J2-2

X6-3

R

O

OR/BK

OR/BK

TEST

SWITCH

LWCO

PROBE

R

O

R

O

LWCO RESET

X6-5

GPS1

GPS2

GPS3

R

B

R

O

R

O

X6-15

BLOWER PROVING

SWITCH (LARGE)

R

O

X6-12

BLOWER PROVING

SWITCH (SMALL)

T

X13-1

BLOCKED FLUE

SWITCH

R

P

X6-6

BLOCKED DRAIN

SWITCH

K

B

ENABLE

X8-3

X8-8

X8-2

X8-4

X8-9

X7-1

X7-5

X7-2

X7-6

INLET SENSOR

OUTLET SENSOR (S9)

OUTLET SENSOR (S1)

FLUE SENSOR

FLUE SENSOR (S10)

PRE-MIX SENSOR 1 (S11)

PRE-MIX SENSOR 1 (S13)

PRE-MIX SENSOR 2 (S12)

PRE-MIX SENSOR 2 (S14)

R

W

X4-1

X4-2

X4-3

X8-20

X8-10

X5-8

X5-7

X5-3

X5-9

X5-2

X5-4

X5-10

X5-5

X5-41

X5-6

X5-12

X5-1

"X5"

BLOCK WIRING

IS MODEL

DEPENDANT

K

B

T

L

B

W

/

R

R

W

Y

G

Y

G

R

B

T

X10-1

X1-3

X10-4

X1-1

X1-12

X1-2

X1-4

X10-2

X10-5

X10-3

X10-6

X1-6

L

N

GND

120V

SUPPLY

ON/OFF

SWITCH

GND

GAS VALVE
(SMALL)

GAS VALVE
(LARGE)

K

B

W

R

P

T

R

O

R

O

L

B

R

L

B

X6-18

X6-8

X1-8

G

X6-9

X6-17

SMALL

BLOWER

RELAY

LARGE

BLOWER

RELAY

X2-4

X13-2

X13-3

BLOWER

(SMALL)

BLOWER

(LARGE)

R

K

B

Y

G

W

T

T

K

B

/

W

T

K

B

BK/W

W

/

G

R/W

BK/W

X2-3

X1-7

X1-10

X1-5

FLAME SENSE 2

FLAME SENSE 1

SPARK

GENERATOR

SPARK ROD

X2-5

FLUE DAMPER

TRANSFORMER

X13-4

FLUE DAMPER

24V

TRANSFORMER

L

B

R

R

R

P

K

B

L

B

Y

R

O

BL

Y

BK

X1-2

X1-3

X1-1

INTEGRATED CONTROL

LARGE CONNECTION BOARD

SMALL CONNECTION BOARD

JUNCTION

BOX

X11

X4

CN3

CN1

DU941

USB

INTERFACE

LCD

DISPLAY

BOILER PUMP
CONTACTOR

SYSTEM PUMP
CONTACTOR

DHW PUMP
CONTACTOR

K

B

HIGH VOLTAGE

LOW VOLTAGE
120 VAC

1.5A EACH MAX

Y/BK

CN3-4