External (off-chip) interface, Parameters – Achronix Speedster22i DDR User Manual

Page 11

Advertising
background image

External (off-chip) Interface

The External DDR interface signals (off-chip) from the DDR PHY to the external memory devices are

shown in Table 2 below.

Signal Name

Bus

Width

Direction Description

sd_clk_p

4

Output

SDRAM clock signal

sd_clk_n

4

Output

SDRAM clock signal

sd_cke

4

Output

SDRAM clock enable control signal

sd_odt

4

Output

SDRAM on die termination control signal

sd_ras_n

1

Output

SDRAM RAS control signal

sd_cas_n

1

Output

SDRAM CAS control signal

sd_we_n

1

Output

SDRAM write enable control signal

sd_reset_n

1

Output

SDRAM reset signal

sd_a

16

Output

SDRAM address bus

sd_ba

3

Output

SDRAM bank select

sd_cs_n

4

Output

SDRAM chip select

sd_dm

9

Output

SDRAM data mask

sd_dummy

9

Output

Internal use only. Leave unconnected

sd_dq

72

Inout

SDRAM data bus

sd_dqsn

9

Inout

SDRAM DQS bus, which is used to clock DQ bus

sd_dqsp

9

Inout

SDRAM DQS bus, which is used to clock DQ bus

Table-2: PHY/DDR controller to memory interface signals

Parameters


Parameters that can be set for both the DDR controller and PHY are shown in Table 3 below.

Parameter

Default

Value

(hex)

Valid Values

Description

DSIZE

72

Multiples of 8 from 8-72 Local side data width

NUM_CLK_OUTS

3

1 to 4

Number of clock outputs

CONTROLLER_REFRESH_EN

1'h1

0-1

Enable controller initiated refreshes.
0: Embedded DDR Controller
automatically handles cyclic
autorefreshing of memory.
1: User manually overrides autorefresh
control of memory.

DELAY_ACTIVATE_TO_PRECHARGE

5'h14

4-30 clock cycles

Minimum ACTIVE to PRECHARGE

DELAY_ACTIVATE_TO_RW

4'h7

2-12 clock cycles

Minimum time between ACTIVATE
and READ/WRITE

DELAY_ACTIVATE_TO_ACTIVATE_DIFF_BANK

3'h4

2-6 clock cycles

Minimum time between ACTIVATE to
ACTIVATE in different banks

DELAY_PRECHARGE_TO_ACTIVATE

4'h7

1-12 clock cycles

Minimum PRECHARGE to
ACTIVATE.

DELAY_ACTIVATE_TO_ACTIVATE_SAME_BANK

6'h20

5-42 clock cycles

Minimum ACTIVATE to
ACTIVATE/AUTO-REFRESH in same
bank

BANK_ACTIVATE_PERIOD

6'h20

7-32 clock cycles

Four bank activate period

DELAY_AUTO_REFRESH_TO_ACTIVATE_SAME_BANK

9'h03B

6-511 clock cylces

Minimum AUTO-REFRESH to
ACTIVATE/AUTO-REFRESH in same

UG031, Nov 18, 2014