Figure 12: read interface 2x clock mode – Achronix Speedster22i DDR User Manual

Page 24

Advertising
background image

Figure 12: Read Interface 2X Clock Mode

The following timing diagram illustrates a single read command of burst length 4. The

signals shown in the following diagrams are ports at the (‘ddr3_xSIZE

1

_LOCATION

2

’. Where

1: SIZE = 72, 64, 32, 16, 8 and 2: LOCATION=EN, EC, ES, WN, WC, WS).

Figure 13: Internal Interface Read Protocol Timing Diagram

ddr_int_rd_request

ddr_int_busy_align

ddr_int_addr[33:0]

ddr_int_rddata_valid_align

ddr_int_rddata[287:0]

Speedster22i

DDR

Controller

DDR Driver

Logic

(in Core Fabric)

ddr_int_burst_size[7:0]

ddr_int_rddata_valid_early_align

clk_div2

clk_div2

ddr_int_rd_ request

a 0

ddr_int_ addr[33:0]

ddr_int_ busy_ align

d0

d1

ddr_int_ rddata_ valid_ align

ddr_int_ rddata[ 287:0]

Valid Read Command

4

ddr_int_ burst_size[7:0]

Timing relationship between ddr_int_rd_request and

ddr_int_rddata_valid assertion based on AL/CL configuration

settings, refresh status and status of bank/row begins assessed

24

UG031, Nov 18, 2014