Installing the load cell, Installing the load cell -7 – Dynojet 250: Torque Module User Manual

Page 11

Advertising
background image

TO R Q U E M O D U L E I N S T A L L A T I O N

Load Cell Installation

Version 4

Torque Module Installation and User Guide for Model 250 Dynamometers

1-7

I

NSTALLING

THE

L

OAD

C

ELL

1

Remove the two bolts securing the existing bar on the eddy current brake and
remove the bar.

Figure 1-6: Remove the Bar

2

Install the mounting bracket.
Note: If you already have the newer style bracket attached to your eddy current
brake, skip this step and continue with step 3.
2a

Remove the four bolts securing the existing mounting bracket and set aside.

2b

Install the new mounting bracket using the four bolts you just removed.

2c

Torque the bolts to 100 ft.-lbs.

Figure 1-7: Install the Mounting Bracket

bar

new bracket

old bracket