Torque module calibration – Dynojet 250: Torque Module User Manual

Page 24

Advertising
background image

Torque Module Installation and User Guide for Model 250 Dynamometers

A P P E N D I X A
Torque Module Calibration

A-2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TORQUE MODULE CALIBRATION

After initial calibration, the Torque Module should be Zero Calibrated approximately
every thirty hours of use.
Before proceeding, be sure the eddy current brake (retarder) is free and clear of any
obstructions. There should not be anything resting on the eddy current brake or the
dynamometer drum during this procedure.
1

Launch WinPEP and click the DynoTrac icon.

Figure A-1: Launch WinPEP

The DynoTrac window will appear.

2

Select Options

Display

Eng Torque from the main menu. The gauge needs

to display “Eng Torque” and not “Braking”.

Figure A-2: DynoTrac Window

DynoTrac icon

gauge displays

engine torque

main menu