Dynojet 250: Torque Module User Manual

Page 21

Advertising
background image

U S I N G T H E TO R Q U E M O D U L E

Torque Cell Calibration

Version 3

Torque Module Installation and User Guide for Model 250 Dynamometers

2-5

8

Install the calibration arm and weights.
8a

Insert the stud on the end of the calibration arm into the bracket on the
mounting plate on the front of the eddy current brake.

8b

Insert the cotter pin in the small hole on the stud. This will secure the
calibration arm during the calibration process.

Note: If the calibration arm is not level, you will need to use the spacer included.
8c

Place the weight support pin in the end of the calibration arm.

8d

Gently place the weights on the calibration arm.

The calibration weights are very heavy. The weights must be set on the arm
gently or you will damage the load cell.

Figure 2-5: Install Calibration Arm and Weights

stud

cotter pin

bracket

connecting arm

with extension

weights

weight support pin

mounting plate

insert spacer if arm

is not level

Advertising