Product Description

4

AT8242

www.kontron.com

Temperature

Meets test profile based on GR-63, EN 300 019-2-3 Class 3.1E, EN 300 019-2-2 Class 2.3
Operating short term: 0°C to +55 °C
Operating long term: 0°C to +45 °C
Non-operating: -40 °C to +85 °C

Humidity

The product meets test profile based on GR-63, EN 300 019-2-3 Class 3.1E, EN 300 019-2-2 Class 2.3

and EN 300 019-2-1 Class 1.2
Operating: 5%-93% (non-condensing) at 40°C
Non-Operating: 5%-93% (non-condensing) at 40°C

Altitude

Designed to meet the following requirements according to Belcore GR-63, section 4.1.3:
Operating: -300 m to 4,000 m (13123 ft) (GR63 4.1.3) at aisle-ambient temperature of 40 deg C;

may require additional cooling above 1800m (5905ft)
Non-Operating: -300 m to 14,000 m (45931.2 ft)

Shock and Vibration and

Bump

Test profile based on EN 300 019-2-3, class 3.2
Shock profile: 11 ms half sine, 3 g, 3 shocks in each direction.
Meets Operational Swept Sine Vibration: test profile based on GR-63, clause 5.4.2, and ETSI EN 300

019-2-3, class 3.2.
(5 to 200 Hz at 0.2 g)
Meets Operational Random Vibration: test profile based on ETSI EN 300 019-2-3, class 3.2
• 5 Hz to 10 Hz @ +12 dB/oct (slope up)
• 10 Hz to 50 Hz @ 0.02 m2/s3 (0.0002 g2/ Hz) (flat)
• 50 Hz to 100 Hz @ -12 dB/oct (slope down)
• 30 minutes per each 3 axes
Free Fall: designed to meet Bellcore GR-63, Section 5.3.
• Packaged -1000 mm, six surfaces, three edges and four corners
• Unpackaged - 100 mm, two sides and two bottom corners

Compliance / Regulatory

Designed to meet the following environmental, safety and EMC requirements:
EN 300 019; Telcordia GR-63; Telcordia SR-3580 level 3; Telcordia GR-1089; Designed to meet Class B

emissions limits, for a system-level goal of Class A with 6 dB margin

Electromagnetic

Compatibility (EMC)and

Interference (EMI)

Meets all emission and immunity requirements of FCC Part 15, GR-1089, EN 300 386, EN 55022 and

EN 55024
Meets GR-1089 (3.1.2) radiated emissions requirements from 10 kHz to 10 GHz, class A
Meets GR-1089 conducted emissions requirements from 10 kHz to 30 MHz, class A
Meets all requirements of UL/CSA/EN/IEC 60950-1

Safety

Compliant with the Low Voltage Directive, EC Council Directive 2006/95/EC
Meets electric strength requirements (5.2): Primary to Chassis 1 kV, Primary to secondary 1kV.
(May be higher if maximum working voltage of converter is greater than 72 Vdc)
Meets the Telcordia GR-63 material flammability requirement UL 94V-0, or V-1 with oxygen index of

28% or greater