44

AT8242

www.kontron.com

35

Board Reset

Discrete

Board reset type and sources
Sensor type = CFh OEM (Kontron Reset Sensor)
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See OEM sensor table, Sensor type code CFh for sensor definition

36

POST Value

Discrete

Show current postcode value
Sensor type = C6h OEM (Kontron POST value sensor)
Event Reading type code = 6Fh Sensor specific, offset 0 to 7 and 14 are used
See OEM sensor table, Sensor type code C6h for sensor definition

37

POST Error

Discrete

CPU Power On Self Test Error
Sensor type = 0Fh System Firmware Progress
Event Reading type code = 6Fh Sensor specific, offset 0 is used
See IPMI v1.5 table 36.3, Sensor type code 0Fh for sensor definition

38

Boot Error

Discrete

Boot Error
Sensor Type = 1Eh Boot Error
Reading type code = 6Fh Sensor Specific, offset 0 is used
See IPMI v1.5 table 36.3, Sensor type code 1Eh for sensor definition

39

Diag Status

Discrete

Diagnostic Status
Sensor Type = C9h OEM (Kontron Diagnostic Status Sensor)
Event Reading type code = 6Fh Sensor Specific, offset 0 to 2 are used
See OEM sensor table, Sensor type code C9h for sensor definition

40

Fwupg Status

Discrete

System Firmware Update Status
Sensor type = CAh OEM (Kontron OEM System firmware upgrade Status)
Event Reading type code = 6Fh Sensor specific, offset 0 to 2 are used
See OEM table, Sensor type code CAh for sensor definition

41

IPMI Watchdog

Discrete

IPMI Watchdog (payload watchdog)
Sensor type = 23h Watchdog 2
Event Reading type code = 6Fh Sensor specific, offset 0,1,2,3,8 are used
See IPMI v1.5 table 36.3, Sensor type code 23h for sensor definition

42

Ver Change IPMC

Discrete

IPMC Firmware Change Detection
Sensor type = 2Bh Version Change
Event Reading type code = 6Fh Sensor specific
See IPMI v1.5 table 36.3, Sensor type code 2Bh for sensor definition

43

Ver Change FPGA

Discrete

FPGA Firmware Change Detection
Sensor type = 2Bh Version Change
Event Reading type code = 6Fh Sensor specific
See IPMI v1.5 table 36.3, Sensor type code 2Bh for sensor definition

44

Health Error

Discrete

General health status, Aggregation of critical sensors. This list is flexible and

could be adjusted based on customer requirements.
Sensor type = 24h Platform Alert
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See IPMI v1.5 table 36.3, Sensor type code 24h for sensor definition

45

IPMB0 Link State

Discrete

IPMB-0 fault detection sensor
Sensor type = F1h PICMG Physical IPMB-0
Event Reading type code = 6Fh Sensor specific
See PICMG 3.0 R3.0 Table 3-69, “Physical IPMB-0 event message”

46

FRU0 IPMBL State

Discrete

IPMB-L branch from FRU0 fault detection sensor
Sensor type = C3h OEM (Kontron OEM IPMB-L link state)
Event Reading type code = 6Fh Sensor specific, offset 2 and 3 are used
See OEM table, Sensor type code C3h for sensor definition

ID

Sensor Name

Sensor Class

Description (Sensor Type, Event trigger)