44
www.kontron.com
35
Board Reset
Discrete
Board reset type and sources
Sensor type = CFh OEM (Kontron Reset Sensor)
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See OEM sensor table, Sensor type code CFh for sensor definition
36
POST Value
Discrete
Show current postcode value
Sensor type = C6h OEM (Kontron POST value sensor)
Event Reading type code = 6Fh Sensor specific, offset 0 to 7 and 14 are used
See OEM sensor table, Sensor type code C6h for sensor definition
37
POST Error
Discrete
CPU Power On Self Test Error
Sensor type = 0Fh System Firmware Progress
Event Reading type code = 6Fh Sensor specific, offset 0 is used
See IPMI v1.5 table 36.3, Sensor type code 0Fh for sensor definition
38
Boot Error
Discrete
Boot Error
Sensor Type = 1Eh Boot Error
Reading type code = 6Fh Sensor Specific, offset 0 is used
See IPMI v1.5 table 36.3, Sensor type code 1Eh for sensor definition
39
Diag Status
Discrete
Diagnostic Status
Sensor Type = C9h OEM (Kontron Diagnostic Status Sensor)
Event Reading type code = 6Fh Sensor Specific, offset 0 to 2 are used
See OEM sensor table, Sensor type code C9h for sensor definition
40
Fwupg Status
Discrete
System Firmware Update Status
Sensor type = CAh OEM (Kontron OEM System firmware upgrade Status)
Event Reading type code = 6Fh Sensor specific, offset 0 to 2 are used
See OEM table, Sensor type code CAh for sensor definition
41
IPMI Watchdog
Discrete
IPMI Watchdog (payload watchdog)
Sensor type = 23h Watchdog 2
Event Reading type code = 6Fh Sensor specific, offset 0,1,2,3,8 are used
See IPMI v1.5 table 36.3, Sensor type code 23h for sensor definition
42
Ver Change IPMC
Discrete
IPMC Firmware Change Detection
Sensor type = 2Bh Version Change
Event Reading type code = 6Fh Sensor specific
See IPMI v1.5 table 36.3, Sensor type code 2Bh for sensor definition
43
Ver Change FPGA
Discrete
FPGA Firmware Change Detection
Sensor type = 2Bh Version Change
Event Reading type code = 6Fh Sensor specific
See IPMI v1.5 table 36.3, Sensor type code 2Bh for sensor definition
44
Health Error
Discrete
General health status, Aggregation of critical sensors. This list is flexible and
could be adjusted based on customer requirements.
Sensor type = 24h Platform Alert
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See IPMI v1.5 table 36.3, Sensor type code 24h for sensor definition
45
IPMB0 Link State
Discrete
IPMB-0 fault detection sensor
Sensor type = F1h PICMG Physical IPMB-0
Event Reading type code = 6Fh Sensor specific
See PICMG 3.0 R3.0 Table 3-69, “Physical IPMB-0 event message”
46
FRU0 IPMBL State
Discrete
IPMB-L branch from FRU0 fault detection sensor
Sensor type = C3h OEM (Kontron OEM IPMB-L link state)
Event Reading type code = 6Fh Sensor specific, offset 2 and 3 are used
See OEM table, Sensor type code C3h for sensor definition
ID
Sensor Name
Sensor Class