Table 4-49:IPMB-L Link State sensor

Table 4-50:FRUInfo Agent sensor

Event/Reading Type Code

Sensor Type

Sensor Specific Offset Event Trigger

6Fh

Standard IPMI

sensor specific

C3h

OEM Kontron

IPMB-L Link

02h IPMB-L Disable

Event Data 2: always 0

Event Data 3:

bit[7:3]: always 0

bit [2:0]:

0h = no failure

1h = Unable to drive clock HI

2h = Unable to drive data HI

3h = Unable to drive clock LO

4h = Unable to drive data LO

5h = clock low timeout

6h = Under test (the IPM Controller

is attempting to determine

who is causing a bus hang)

07h = Undiagnosed

Communication Failure

03h IPMB-L Enable

Event/Reading Type Code

Sensor Type

Sensor Specific Offset Event Trigger

0Ah

Standard IPMI

Discrete

C5h

OEM Kontron

FRU Info Agent

00h Device running

Event Data 2 is used a bit flag error
Bit 7: unspecifiedError
Bit 6: notPresentError
Bit 5: multirecHeaderError
Bit 4: multirecDataError
Bit 3: timeout error
Bit 2: ipmcError
Bit 1: fruDataError
Bit 0: commonHeaderError

Event Data 3 is used a bit flag error
Bit 7: SetClockState Not Supported
Bit 6: SetClockState Error
Bit 5: SetPortState Not Supported
Bit 4: SetPortState Error
Bit 3: Clock Internal mismatch
Bit 2: Clock Match Error
Bit 1: Internal mismatch
Bit 0: Match Error, Not in single link
matches

01h Device in test /
Fia running

02h Power Off, FRU
not present

06h Transition to
degraded

08h Install Error