Kontron AT8242 User Manual

Page 61

Advertising
background image

45

AT8242

www.kontron.com

47

FRU3 IPMBL State

Discrete

IPMB-L branch from FRU3 fault detection sensor
Sensor type = C3h OEM (Kontron OEM IPMB-L link state)
Event Reading type code = 6Fh Sensor specific, offset 2 and 3 are used
See OEM table, Sensor type code C3h for sensor definition

48

FRU Over Icc

Discrete

FRU Over Current Sensor
Sensor type = CBh OEM (Kontron OEM FRU Over Current)
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See OEM table, Sensor type code CBh for sensor definition

49

FRU Sensor Error

Discrete

FRU Error during external FRU Sensor discovery
Sensor type = CCh OEM (Kontron OEM FRU sensor error)
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See OEM table, Sensor type code CCh for sensor definition

50

FRU Pwr Denied

Discrete

FRU Power Denial Detection
Sensor type = CDh OEM (Kontron FRU Power denied)
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See OEM table, Sensor type code CDh for sensor definition

51

FRU MngtPwr Fail

Discrete

FRU Management Power Fail
Sensor type = D2h OEM (Kontron FRU Management Power Fail)
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See OEM table, Sensor type code D2h for sensor definition

52

FRU0 Agent

Discrete

FRU Information Agent - FRU0 Data Error Detection
Sensor type = C5h OEM (Kontron FRU Info Agent)
Event Reading type code = 0Ah Generic Discrete, offset 6,8 are used
See OEM table, Sensor type code C5h for sensor definition

53

FRU1 Agent

Discrete

FRU Information Agent - FRU1 Data Error Detection
Sensor type = C5h OEM (Kontron FRU Info Agent)
Event Reading type code = 0Ah Generic Discrete, offset 6,8 are used
See OEM table, Sensor type code C5h for sensor definition

54

FRU2 Agent

Discrete

FRU Information Agent - FRU2 Data Error Detection
Sensor type = C5h OEM (Kontron FRU Info Agent)
Event Reading type code = 0Ah Generic Discrete, offset 6,8 are used
See OEM table, Sensor type code C5h for sensor definition

55

FRU3 Agent

Discrete

FRU Information Agent - FRU3 Data Error Detection
Sensor type = C5h OEM (Kontron FRU Info Agent)
Event Reading type code = 0Ah Generic Discrete, offset 6,8 are used
See OEM table, Sensor type code C5h for sensor definition

56

EventRcv ComLost

Discrete

Detects communication with the event receiver (ShMC) has been lost
Sensor type = 1Bh Cable/Interconnect
Event Reading type code = 03h Digital Discrete
See IPMI v1.5 table 36.2 and table 36.3 for sensor definition

57

IPMC Reboot

Discrete

IPMC reboot detection
Sensor type = 24h Platform Alert
Event Reading type code = 03h Digital Discrete, offset 0,1 are used
See IPMI v1.5 table 36.3, Sensor type code 24h for sensor definition

58

IPMC Storage Err

Discrete

Management sub-system health: non volatile memory error
Sensor type = 28h Management Subsystem Health
Event Reading type code = 6Fh Sensor specific, offset 1 is used
See IPMI v1.5 table 36.3, Sensor type code 28h for sensor definition

ID

Sensor Name

Sensor Class

Description (Sensor Type, Event trigger)