Kontron AT8242 User Manual

Page 66

Advertising
background image

50

AT8242

www.kontron.com

4.3.3.2

Carrier Activation and Carrier Information Tables

Each NPU engine is seen as a virtual AMC, with its own power and reset domain. Even though they are not
physically extractable, relevant carrier information records are present in FRU data as to insure proper
compatibility with the AMC.0 R2.0 specification.

Table 4-23:Carrier Activation and Current Management

Link Descriptor

00132F42h

Link Grouping ID (Bits 31-24)

00h: Single-channel link

Link Type Extension (Bits 23-20)

1h: Fixed 40GBASE-KR4

Link Class (bits 19-16)

3h: 10.3125Gbd Signaling Link Class

Link Type (Bits 15-12)

2h: PICMG 3.1 Ethernet Fabric Interface

Link Designator (Bits 11-0)

F42h: Fabric Interface, Channel 2, Port 0, 1, 2, 3

Link Descriptor

00032142h

Link Grouping ID (Bits 31-24)

00h: Single-channel link

Link Type Extension (Bits 23-20)

0h: Fixed 10GBASE-KR

Link Class (bits 19-16)

3h: 10.3125Gbd Signaling Link Class

Link Type (Bits 15-12)

2h: PICMG 3.1 Ethernet Fabric Interface

Link Designator (Bits 11-0)

142h: Fabric Interface, Channel 2, Port 0

Field

Value

Record Type ID

C0h

Record Format Version

02h

Record Length

*Calculated

Record Checksum

*Calculated

Header Checksum

*Calculated

Manufacturer ID

00315Ah (PICMG Record ID)

PICMG Record ID

17h (Carrier Activation and Current Management

Record)

Record Format Version

00h

Maximum Internal Current

50h (8 Amps at 12V => 96 Watts)

Allowance for Module Activation

Readiness

02h

Module Activation and Power

Descriptor Count

02h

Carrier Activation and Power

Descriptor

7A28FFh

Local IPMB-L Address

7Ah

Maximum Module Current

28h (4 Amps at 12V => 48 Watts)

Reserved

FFh

Field

Value

Advertising