66

AT8242

www.kontron.com

Table 4-51:POST Value sensor

Table 4-52:Diag Status sensor

Table 4-53:Fwupg Status sensor

Table 4-54:FRU Over Icc sensor

Table 4-55:FRU Sensor Error sensor

Event/Reading Type Code

Sensor Type

Sensor Specific Offset Event Trigger

6Fh

Standard IPMI

sensor specific

C6h

OEM Kontron

POST Code Value

00h to 07h

POST code LOW byte value, no event gener-
ated on these offsets

14h

POST Code Error Event Trigger
Event Data 2: POST Low Nibble
Event Data 3: POST High Nibble

Event/Reading Type Code

Sensor Type

Sensor Specific Offset Event Trigger

6Fh

Standard IPMI

sensor specific

C9h

OEM Diagnostic Status

00h

Diagnostic Started

01h

Diagnostic PASSED

02h

Diagnostic FAILED

Event/Reading Type Code

Sensor Type

Sensor Specific Offset Event Trigger

6Fh

Standard IPMI

sensor specific

CAh

OEM System Firmware

Upgrade Status

00h

Upgrade Started

01h

Upgrade PASSED

02h

Upgrade FAILED

Event/Reading Type Code

Sensor Type

Sensor Specific Offset Event Trigger

03h

Standard IPMI

Discrete

CBh

OEM Kontron FRU Over Cur-

rent

00h
01h
State Asserted /
State Deasserted

Event Data 2:
00h: Over Current on Management power.
01h: Over Current on Payload power.

Event Data 3:FRU ID

Event/Reading Type Code

Sensor Type

Sensor Specific Offset Event Trigger

03h

Standard IPMI

Discrete

CCh

OEM Kontron FRU Sensor

Error

00h
01h
State Asserted /
State Deasserted

Event Data 2:
undefined

Event Data 3:FRU ID