Thermal Considerations

80

AT8242

www.kontron.com

IPMI non-recoverable / PICMG 3.0 critical/ telco critical:

Temperature has reached a destructive level. Device might be damaged.

Most ATCA chassis react to temperature events in the following manner: When a minor threshold is reached,
the shelf manager will incrementally increase airflow (fan speed) to bring the temperature below the crossed
threshold. When a major threshold is reached, the shelf manager will increase the fans to maximum speed.
When a critical threshold is reached, the shelf manager wills shutdown the blade to prevent damage. The
shelf alarm panel, when available, can inform the operator with LEDs when an alarm (minor, major, critical)
is raised. Refer to your chassis documentation to adapt and optimize your temperature monitoring
application to chassis capabilities. See also System Airflow section for more information.

Below is the list of temperature sensors with their respective thresholds.

Table 6-1:IPMC Temperature Sensors Thresholds

Table 6-2:MMC Temperature Sensors Thresholds (Same list for both NPU)

Sensor ID

Lower Thresholds

Upper Thresholds

Lower Non-

Recoverable

Lower Critical

Lower Non-

Critical

Upper Non-

Critical

Upper Critical

Upper Non-

Recoverable

Temp Inlet

N/A

-5°C

0°C

60°C

70°C

75°C

Temp Outlet

N/A

N/A

N/A

75°C

85°C

100°C

Temp IPMC

N/A

-5°C

0°C

90°C

100°C

110°C

Temp Switch

N/A

-5°C

0°C

85°C

95°C

100°C

Temp SO-DIMM

N/A

-5°C

0°C

75°C

85°C

95°C

Sensor ID

Lower Thresholds

Upper Thresholds

Lower Non-

Recoverable

Lower Critical

Lower Non-

Critical

Upper Non-

Critical

Upper Critical

Upper Non-

Recoverable

Temp DIMM#4

-10°C

0°C

5°C

75°C

85°C

95°C

Temp DIMM#3

-10°C

0°C

5°C

75°C

85°C

95°C

Temp DIMM#2

-10°C

0°C

5°C

75°C

85°C

95°C

Temp DIMM#1

-10°C

0°C

5°C

75°C

85°C

95°C

Temp NPU

N/A

-5°C

0°C

91°C

101°C

106°C

Temp Vcore

N/A

N/A

N/A

75°C

85°C

95°C

Advertising