10 feature connector (feature) (j30), Feature connector (feature) (j30), Internal connectors – Kontron KTQ67-FLEX User Manual

Page 48

Advertising
background image

KTQ67 Users Guide

KTD-N0829-G Page 48

6.10

Feature Connector (FEATURE) (J30)

Note

Pull

U/D

Ioh/Iol

Type

Signal

PIN

Signal

Type

Ioh/Iol

Pull

U/D

Note

2

2M/

-

I

CASE_OPEN#

1

2

SMBC

/4mA

10K/

1

-

25/25mA

O

S5#

3

4

SMBD

/4mA

10K/

1

-

25/25mA

O

PWR_OK

5

6

EXT_BAT PWR

-

-

-

O

FAN3OUT

7

8

FAN3IN

I

-

-

-

-

PWR

SB3V3

9 10

SB5V

PWR

-

-

-

IOT

GPIO0

11 12

GPIO1

IOT

-

-

IOT

GPIO2

13 14

GPIO3

IOT

-

-

IOT

GPIO4

15 16

GPIO5

IOT

-

-

IOT

GPIO6

17 18

GPIO7

IOT

-

-

-

PWR

GND

19 20

GND

PWR

-

-

-

I

GPIO8

21 22

GPIO9

I

-

-

I

GPIO10

23 24

GPIO11

I

-

-

I

GPIO12

25 26

GPIO13

IOT

-

-

IOT

GPIO14

27 28

GPIO15

IOT

-

-

IOT

GPIO16

29 30

GPIO17

IOT

-

-

-

PWR

GND

31 32

GND

PWR

-

-

-

8/8mA

O

EGCLK

33 34

EGCS#

O

8/8mA

-

-

8/8mA

EGAD

35 36

TMA0

O

-

PWR

+12V

37 38

GND

PWR

-

-

-

O

FAN4OUT

39 40

FAN4IN

I

-

-

-

-

PWR

GND

41 42

GND

PWR

-

-

-

-

PWR

GND

43 44

S3#

O

25/25mA

-


Notes: 1. Pull-up to +3V3Dual (+3V3 or SB3V3). 2. Pull-up to on-board Battery.

Signal

Description

CASE_OPEN#

CASE OPEN, used to detect if the system case has been opened. This signal’s status
is readable, so it may be used like a GPI when the Intruder switch is not required.

SMBC

SMBus Clock signal

SMBD

SMBus Data signal

S3#

S3 sleep mode, active low output, optionally used to deactivate external system.

S5#

S5 sleep mode, active low output, optionally used to deactivate external system.

PWR_OK

PoWeR OK, signal is high if no power failures are detected. (This is not the same as
the P_OK signal generated by ATX PSU).

EXT_BAT

(EXTernal BATtery) option for connecting + terminal of an external primary cell battery
(2.5 - 3.47 V) (– terminal connected to GND). The external battery is protected against
charging and can be used with or without the on-board battery installed.

FAN3OUT

FAN 3 speed control OUTput, 3.3V PWM signal can be used as Fan control voltage.

FAN3IN

FAN3 Input. 0V to +3V3 amplitude Fan 3 tachometer input.

FAN4OUT

FAN 4 speed control OUTput, 3.3V PWM signal can be used as Fan control voltage.

FAN4IN

FAN4 Input. 0V to +3V3 amplitude Fan 3 tachometer input.

SB3V3

Max. load is 0.75A (1.5A < 1 sec.)

SB5V

StandBy +5V supply.

GPIO0..17

General Purpose Inputs / Output. These Signals may be controlled or monitored
through the use of the KT-API-V2 (Application Programming Interface).

EGCLK

Extend GPIO Clock signal

EGAD

Extend GPIO Address Data signal

EGCS#

Extend GPIO Chip Select signal, active low

TMA0

Timer Output

+12V

Max. load is 0.75A (1.5A < 1 sec.)

Internal Connectors

Advertising
This manual is related to the following products: