Table 3-66:

0x376: Board Interrupt Pending Register 1

ACTION

D7

D6

D5

D4

D3

D2

D1

D0

READ

0

0

0

Int4

Int3

Int2

Int1

Int0

WRITE

NU

NU

NU

w1c

w1c

w1c

w1c

w1c

POWER UP

0

0

0

0

0

0

0

0

BITFIELD

DESCRIPTION

[D0]

Int0

Interrupt occurred, triggered by CON_IRQ[1]# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active

[D1]

Int1

Interrupt occurred, triggered by CON_IRQ[2]# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active

[D2]

Int2

Interrupt occurred, triggered by CON_IRQ[3]# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active

[D3]

Int3

Interrupt occurred, triggered by CON_IRQ[4]# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active

[D4

Int4

Interrupt occurred, triggered by CON_IRQ[5]# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active

Table 3-67:

0x377: Board Interrupt Pending Register 2

ACTION

D7

D6

D5

D4

D3

D2

D1

D0

READ

Int7

Int6

Int5

Int4

Int3

Int2

Int1

Int0

WRITE

w1c

w1c

w1c

w1c

w1c

w1c

w1c

w1c

POWER UP

0

0

0

0

0

0

0

0

BITFIELD

DESCRIPTION

[D0]

Int0

Interrupt occurred, triggered by CON_SMB_ALERT# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active

[D1]

Int1

Interrupt occurred, triggered by LM73_TEMP_ALERT# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active

[D2]

Int2

Interrupt occurred, triggered by CON_THERM# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active

[D3]

Int3

Interrupt occurred, triggered by CON_PWR_OK line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active

[D4]

Int4

Interrupt occurred, triggered by CON_BATLOW# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active

[D5]

Int5

Interrupt occurred, triggered by RTC_INT# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active

[D6]

Init6

Interrupt occurred, triggered by CON_WAKE0# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active

[D7]

Init7

Interrupt occurred, triggered by CON_WAKE1# line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active