Table 3-68, Table 3-69, Table 3-70 – Kontron COMe-cP2020 User Manual

Page 70

Advertising
background image

www.kontron.com

COMe-P2020 User Guide

70

Register is currently read only, read value is always 0x00.

Table 3-68:

0x378: Board Interrupt Pending Register 3

ACTION

D7

D6

D5

D4

D3

D2

D1

D0

READ

0

0

0

0

0

0

0

Int0

WRITE

NU

NU

NU

NU

NU

NU

NU

w1c

POWER UP

0

0

0

0

0

0

0

0

BITFIELD

DESCRIPTION

[D0]

Int0

Interrupt occurred, triggered by WATCHDOG line. Register is cleared by write to '1':
'0' = no Interrupt
'1' = Interrupt is active

Table 3-69:

0x379: Board Interrupt Pending Register 4

ACTION

D7

D6

D5

D4

D3

D2

D1

D0

READ

0

0

0

0

0

0

0

0

WRITE

NU

NU

NU

NU

NU

NU

NU

NU

POWER UP

0

0

0

0

0

0

0

0

Table 3-70:

0x37A: Board Interrupt Enable Register 1

ACTION

D7

D6

D5

D4

D3

D2

D1

D0

READ

0

0

0

En4

En3

En2

En1

En0

WRITE

NU

NU

NU

En4

En3

En2

En1

En0

POWER UP

0

0

0

0

0

0

0

0

BITFIELD

DESCRIPTION

[D0]

En0

Enable bit for CON_IRQ[1]# Interrupt Request Register:
'0' = no Interrupt
'1' = Interrupt is active

[D1]

En1

Enable bit for CON_IRQ[2]# Interrupt Request Register:
'0' = no Interrupt
'1' = Interrupt is active

[D2]

En2

Enable bit for CON_IRQ[3]# Interrupt Request Register:
'0' = no Interrupt
'1' = Interrupt is active

[D3]

En3

Enable bit for CON_IRQ[4]# Interrupt Request Register:
'0' = no Interrupt
'1' = Interrupt is active

[D4]

En4

Enable bit for CON_IRQ[5]# Interrupt Request Register:
'0' = no Interrupt
'1' = Interrupt is active

Advertising