Table 3-73:

0x37D: Board Interrupt Enable Register 4

ACTION

D7

D6

D5

D4

D3

D2

D1

D0

READ

0

0

0

0

0

0

0

0

WRITE

NU

NU

NU

NU

NU

NU

NU

NU

POWER UP

0

0

0

0

0

0

0

0

Table 3-74:

0x380: Interrupt Multiplexer Register 1

ACTION

D7

D6

D5

D4

D3

D2

D1

D0

READ

MuxSel3

MuxSel2

MuxSel1

MuxSel0

WRITE

MuxSel3

MuxSel2

MuxSel1

MuxSel0

POWER UP

0

0

1

1

0

0

1

0

BITFIELD

DESCRIPTION

[D0-D1]

MuxSel0

Interrupt/GPIO Multiplexer for *UC_IRQ[7]#* line, connected to:

"00" = line is not used
"01" = *CON_IRQ[1]#* line
"10" = IRQ header line (default state!)
"11" = Watchdog line

[D2-D3]

MuxSel1

Interrupt/GPIO Multiplexer for *UC_IRQ[8]#* line, connected to:

"00" = line is not used
"01" = *CON_IRQ[2]#* line
"10" = IRQ header line
"11" = Watchdog line

[D4-D5]

MuxSel2

Interrupt/GPIO Multiplexer for *UC_IRQ[9]#* line, connected to:

"00" = line is not used
"01" = *CON_IRQ[3]#* line
"10" = IRQ header line
"11" = Watchdog line (default state!)

[D6-D7]

MuxSel3

Interrupt/GPIO Multiplexer for *UC_IRQ[10]#* line, connected to:

"00" = line is not used
"01" = *CON_IRQ[4]#* line
"10" = IRQ header line
"11" = Watchdog line

Table 3-75:

0x381: Interrupt Multiplexer Register 2

ACTION

D7

D6

D5

D4

D3

D2

D1

D0

READ

00

00

00

MuxSel5

WRITE

NU

NU

NU

MuxSel5

POWER UP

0

0

0

0

0

0

0

0

BITFIELD

DESCRIPTION

[D0-D1]

MuxSel5

Interrupt/GPIO Multiplexer for *UC_IRQ[11]#* line, connected to:

"00" = line is not used
"01" = *CON_IRQ[5]#* line
"10" = IRQ header line
"11" = Watchdog line