Installation

7

2.0

Installation

This section provides information for connecting the indicator to load cell digital inputs and outputs, and serial
communications cables. Battery installation is also described in this chapter in Section 2.5.

To power up the 120 Plus indicator, press the

ZERO

key on the front panel. The indicator must be installed near an

easily accessible power source or can be operated on an internal battery.

The various sockets on the 120 Plus are shown in Figure 2-1.

Figure 2-1. 120 Plus Cable Connections

2.1

Power Connector

The following table details the power connector pin functions.

2.2

Serial/Print Connector

Table 2-2 details the serial pin connector functions:

The RS-232 EDP port (RS-232C, may be connected to a PC, printer, or remote display) and the printer port (TxD
20 mA, may be connected to a PC, printer or remote display). Connections are shown in Figure 2-2.

Figure 2-2. Connect RS-232 EDP Port to PC

Pin

Designation

Function

1

DC+

Power Source

2

DC-

Power Source

3

Earth

Power Return

Table 2-1. Power Connection Pin Outs

Port

Pin

Designation

Function

EDP Port

2

EDP TxD

RS-232 Transmit Data

6

EDP RxD

RS-232 Receive Data

12

EDP GND

RS-232 Ground or -20 mA Out

Print Port

1

PR: TxD

RS-232 Transmit Data

11

PR: TxD 20 mA

+ 20 mA Out

12

PR: -20 mA OUT

RS-232 Ground or -20 mA Out

Table 2-2. Serial Connector

Load Cell

1

2

3

PC COM1

6

2

12

DB9-F

5

2 3

TxD

RxD

TxD

RxD

GND

HDB15

120 Plus