3 load cell connections, Table 2-5. j15load cell connector, Figure 2-8. 6-wire load cell application – Rice Lake 120 Plus Digital Weight Indicator User Manual

Page 14: 4 optional i/o connections, 1 remote switcher, Table 2-6. remote switcher pin outs

Advertising
background image

10

120Plus Digital Weight Indicator Technical Manual

2.3

Load Cell Connections

The following table shows the load cell connection pins to the CPU.

6-Wire Load Cell Connection with Optional Quick Disconnect

Figure 2-8. 6-Wire Load Cell Application

2.4

Optional I/O Connections

The optional I/O board provides three digital inputs and two isolation digital relay outputs.

2.4.1

Remote Switcher

The 120 Plus indicator has provisions to connect an external input device such as a press switch (purchased
separately) to provide a keypad function. The keypad function can be set in the SETPNT menu; the external device
must provide a normally open (N.O.) momentary switch contact. The remote switch input requires a voltage free
contact between RSW input and GND.

Figure 2-9. Connect Remote Switcher Inputs to an External Input Device

The following table displays the pins and port functions of the female HDB15.

J1 Pin

Load Cell Connections on the CPU Board

1

- Excitation

2

- Sense

3

- Signal

4

+ Signal

5

+ Sense

6

+ Excitation

Table 2-5. J15Load Cell Connector

Pin

Port

Function

4

Out 1/2 Com

Setpoint 1 and 2 common

5

Out 2

Setpoint 2

7

RSW 1/2/3

Remote switcher 1, 2, and 3 ground

10

Out 1

Setpoint 1

13

RSW 1

Remote switcher 1

14

RSW 2

Remote switcher 2

15

RSW 3

Remote switcher 3

Table 2-6. Remote Switcher Pin Outs

Load Cell

SIGNAL

-

SENSE

-

SENSE

+

120 Plus

SIGNAL

+

EXITATION

+

EXCITATION

-

HDB15

7

15

14

13

RSW1

RSW2

RSW3

120 Plus

Advertising