39

8.1.7

Print Format Commands

8.1.8

Set Points Commands

Command

Description

Values

WWPF

Print format strings in visible ASCII characters

See "Print Formats"

WPF

Print format strings in ASCII hex code

See "Print Formats"

Table 8-7. PFROMT Commands

Command

Description

Values

S1.KIND

Kinds of Operation mode for set point 1 OFF, GROSS, NET, DISPLA, ABSNET

S1.CONTACT

Contact status below the set point 1
value

N.CLOSE, N.OPEN

S1.CONDITI

Output enabled only after the weight
reading has stabilized

NORMAL, STABLE

S1.WAVL

Set weight thresholds for set point 1.
Output 1 active if load over this weight
(load >= wval)

0 - 999999

S1.HYSTER

Set weight thresholds for set point 1.
Output 1 deactive if load under this
weight (load < wval
x hysteresis)

0%, 2%, 5%, and 10%

S1.TIMER

Output is disabled after the time period
has expired

None, 250ms, 500ms, 750ms, 1.5Sec, 3.0Sec, 4.0Sec, 5.0Sec

S1.DELAY

Time delay before the output is enabled None, 250ms, 500ms, 750ms, 1.5Sec, 3.0Sec, 4.0Sec, 5.0Sec

S1.BUZZER

Enable/Disable set point

OFF, ON

S2.KIND

Kinds of Operation mode for set point 2 OFF, GROSS, NET, DISPLA, ABSNET

S2.CONTACT

Contact status below the set point 2
value

N.CLOSE, N.OPEN

S2.CONDITI

Output enabled only after the weight
reading has stabilized

NORMAL, STABLE

S2.WAVL

Set weight thresholds for set point 2.
Output 2 active if load over this weight
(load >= wval)

0 - 999999

S2.HYSTER

Set weight thresholds for set point 2.
Output 2 deactive if load under this
weight. (load < wval x hysteresis)

0%, 2%, 5%, and 10%

S2.TIMER

The output is disabled after the time
period has expired

None, 250 ms, 500 ms, 750 ms, 1.5 sec, 3.0 sec, 4.0 sec, 5.0
sec

S2.DELAY

Time delay before the output is enabled None, 250 ms, 500 ms, 750 ms, 1.5 sec, 3.0 sec, 4.0 sec, 5.0

sec

S2.BUZZER

Enable/Disable set point

OFF, ON

RSWDEF

Specifies the function activated by
remote switch inputs 1, 2, and 3.

OF.OF.OF, PR.TA.ZO, UN.TA.ZO