DIG I/O Menu

Parameter

Choices

Description

Level 2 submenus

SLOTx

BIT y

Lists available digital I/O slots.

Level 3 submenus

BIT y

OFF
INPUT
OUTPUT
PROGIN
ZERO
NT/GRS
TARE
UNITS
PRINT
ACCUM
SETPNT
TIMDATE
ESC
CLEAR
DSPTAR
IDKEY
KEY0—KEY9
KEYDP
ENTER
NAVUP
NAVDN
NAVLFT
NAVRGT
KBDLOC
HOLD
BATRUN
BATSTRT
BATPAUS
BATRESET
CLRCN
GROSS
NET
PRIM
SEC
TER
CLRTAR
CLRACC

Specifies the function of the digital I/O bit.

• OFF indicates that the bit is not configured.
• INPUT assigns the bit as a digital input used for DIGIN setpoints.
• OUTPUT assigns the bit as a digital output for setpoint or program use.
• PROGIN assigns the bit as a digital input used to generate a program event.
• ZERO, NT/GRS (net/gross mode toggle), TARE, UNITS, and PRINT provide the same

functions as the five major front panel keys.

• ACCUM adds the current scale weight to the accumulator, if the scale accumulator is

enabled.

• SETPNT, and TIMDATE provide the same functions as the Setpoint and Time/Date softkeys.
• ESC provides a function equivalent to the Cancel softkey.
• CLEAR simulates pressing the front panel CLR key.
• DSPTAR displays the current tare; equivalent to pressing the Display Tare softkey.
• IDKEY displays a prompt to enter a new unit ID; equivalent to pressing the Unit ID softkey.
• KEY0—KEY9 and KEYDP (decimal point) simulate pressing keys on the numeric keypad.
• ENTER simulates pressing the front panel ENTER key.
• NAVUP, NAVDN, NAVLFT, and NAVRGT simulate pressing the navigation keys.
• KBDLOC locks the keyboard (indicator front panel) when held low.
• HOLD holds the current display. Releasing this input clears the running average filter.
• BATRUN allows a batch routine to be started and run. With BATRUN active (low), the

BATSTRT input starts the batch; if BATRUN is inactive (high), BATSTRT cancels the batch.

• BATSTRT starts or ends a batch routine, depending on the state of the BATRUN input.
• BATPAUS pauses a batch routine when held low.
• BATRESET resets the batch sequence.
• CLRCN resets the consecutive number to the value specified on the CONSTUP parameter

(FEATURE menu).

• GROSS, NET, PRIM, SEC, and TER select gross or net weight display, and primary,

secondary, or tertiary units display modes.

• CLRTAR clears the current tare.
• CLRACC clears the active accumulator.

Table 3-7. DIG I/O Menu Parameters