DIGOUT

bit_number

Lists all digital output bits available for the specified SLOT. This parameter is used to
specify the digital output bit associated with this setpoint.

For continuous setpoints, the digital output becomes active (low) when the condition
is met; for batch setpoints, the digital output is active until the setpoint condition is
met.

BRANCH

0
1-100

Specifies the setpoint number to which the batch sequence is to branch if the
current setpoint is not satisfied upon initial evaluation.

The special value zero indicates that no branch is taken.

TIME

time

For TOD setpoints, specifies the time at which the setpoint becomes active. The
format used to enter the time (12-hour or 24-hour) is based on the value specified for
the TIMEFMT parameter on the FEATURE menu.

DURATION

hh:mm:ss

For TOD setpoints, specifies the length of time that the digital output associated with
this setpoint changes state. The value is entered in hours, minutes, and seconds
(hh:mm:ss). All other operations associated with this setpoint (print, tare, or
accumulate) are performed at the end of the specified duration.

NSAMPLE

1–65535

For AVG setpoints, specify the number of A/D samples used to calculate the average
weight.

SOURCE

source_scale

Specify the scale number used as the source for the setpoint.

DIN SLOT

slot_number

For DIGIN setpoints, specify the slot number from which digital inputs will be read.

DIN MASK

digital_input_mask

For DIGIN setpoints, specify the bits used as inputs to the setpoint. Use the Select
softkey to select bits.

VUNDER

0–9999999

For CHKWEI setpoints, specifies the lower weight limit.

VOVER

0–9999999

For CHKWEI setpoints, specifies the upper weight limit.

DUNDER

digital_output

For CHKWEI setpoints, specifies the bit number of digital output activated when the
scale weight is less than the VUNDER value specified.

DACCEPT

digital_output

For CHKWEI setpoints, specifies the bit number of digital output activated when the
scale weight between the VUNDER and VOVER values specified.

DOVER

digital_output

For CHKWEI setpoints, specifies the bit number of digital output activated when the
scale weight is greater than the VOVER value specified.

COAST

0–65535

For PLSCNT setpoints, specifies the time delay (in 0.1-second intervals) inserted
between reaching the setpoint target value and capture of the actual pulse count.

SETPTS Menu

Parameter

Choices

Description

Table 8-2. Setpoint Menu Parameters (Continued)