Data Editing

104

PowerScan

®

PD7100 Corded

Label ID — continued

Table 18. Label ID Examples

STEP

ACTION

EXAMPLES

1.

Scan the ENTER/EXIT barcode

(Scanner enters Programming Mode)

2.

Determine placement of the Label
ID characters BEFORE or AFTER
with regard to scanned data using

Label ID Control on
page 105

Enable as Prefix

Enable as Suffix

Enable as Prefix

Enable as Suffix

3.

Scan the barcode selecting the
symbology type you wish to
designate label ID characters for
using

Label ID Symbology

Selection, starting on page
106

.

GS1 DataBar

Omnidirectional

Code 39

Interleaved 2 of 5

Code 32

4.

Custom Label ID example (desired
characters):

D B *

= C 3

+

P H

5.

Find hex equivalents from the
ASCII table (inside back cover),
then scan in these digits/
characters using the barcodes in
the section:

Keypad, starting

on page 295

. f you make a

mistake before the last character,
scan the CANCEL barcode to
abort and not save the entry
string. You can then start again at
the beginning.

44 42 2A

3D 43 33

2B

50 48

6.

Scan theENTER/EXIT barcode

(Scanner exits Label ID entry)

7.

Scan the ENTER/EXIT barcode
once again

(Scanner exits Programming Mode)

Result:

DB*[barcode data] [barcode data]=C3

+[barcode data]

[barcode data]PH