Ack nak retry count – Rice Lake Datalogic PowerScan PD7100 Series Laser Scanner User Manual

Page 72

Advertising
background image

RS-232/USB-Com Interfaces

64

PowerScan

®

PD7100 Corded

ACK NAK Retry Count

This feature specifies the number of times the reader retries a label transmission due
to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0
disables the count, and a selection of 255 specifies unlimited retries.

To set this feature:

1. Determine the desired setting.

2. Pad the number with leading zeroes to yield three digits. For example: 0 = 000, 5 =

005, 20 = 020, etc.

3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-

ming Mode.

4. Scan the barcode: SELECT ACK NAK RETRY COUNT SETTING.

5. Scan the appropriate three digits from the keypad in

Appendix E, Keypad

, that

represent the number which was determined in the steps above. You will hear a
two-beep indication after the last character.

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-

ming Mode.

This completes the procedure. See

Table 11

for some examples of how to set this

feature.

Table 11. ACK NAK Retry Count Setting Examples

NOTE

If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.

STEP

ACTION

EXAMPLES

1

Desired Setting

Disable Retry

Count

3 Retries

54 Retries

Unlimited Retries

2

Pad with leading zero(es)

000

003

054

255

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT ACK NAK RETRY COUNT SETTING

5

Scan Three Characters From

Appendix E, Keypad

‘0’, ‘0’ and ‘0’

‘0’, ‘0’ and ‘3’

‘0’, ‘5’ and ‘4’

‘2’, ‘5’ and ‘5’

6

Scan ENTER/EXIT PROGRAMMING MODE

Advertising