Label gone timeout – Rice Lake Datalogic PowerScan PD7100 Series Laser Scanner User Manual

Page 27

Advertising
background image

Label Gone Timeout

Product Reference Guide

19

Label Gone Timeout

This feature sets the time after the last label segment is seen before the reader prepares for
a new label. The timeout can be set within a range of 10 milliseconds to 2,550 millisec-
onds (2.55 seconds) in 10ms increments. Label Gone Timeout does not apply to scan
modes that require a trigger pull for each label that is read

Follow these instructions to set this feature:

1. Determine the desired setting in milliseconds.

2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result

with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020,
etc.

3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-

ming Mode.

4. Scan the barcode: SELECT LABEL GONE TIMEOUT SETTING.

5. Scan the appropriate three alpha-numeric characters from the keypad in

Appendix

E, Keypad

representing the duration which was determined in the steps above. You

will hear a two-beep indication after the last character.

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-

ming Mode.

This completes the procedure. See

Table 2

for some examples of how to set this feature.

Table 2. Timeout Setting Examples

NOTE

If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.

STEP

ACTION

EXAMPLES

1

Desired Setting

50ms

150ms

1800ms (1.8 sec.)

2550ms (2.55 sec.)

2

Divide by 10 (and pad with leading
zeroes)

005

015

180

255

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT LABEL GONE TIMEOUT SETTING

5

Scan Three Characters From

Appendix E, Keypad

‘0’, ‘0’ and ‘5’

‘0’, ‘1’ and ‘5’

‘1’, ‘8’ and ‘0’

‘‘2’, ‘5’ and ‘5’

6

Scan ENTER/EXIT PROGRAMMING MODE

Advertising