Intercode Delay

Product Reference Guide

83

Intercode Delay

Specifies the delay between labels transmitted to the host for this interface. The selectable
range for this feature is from 0 to 99 seconds.

Follow these instructions to set this feature:

1. Determine the desired setting.

2. Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 =

05, 20 = 20, etc

3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-

ming Mode.

4. Scan the barcode: SELECT INTERCODE DELAY SETTING.

5. Scan the appropriate two digits from the keypad in

Appendix E, Keypad

, that rep-

resent the duration which was determined in the steps above. You will hear a two-
beep indication after the last character.

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-

ming Mode.

This completes the procedure. See

Table 16

for some examples of how to set this feature.

Table 16. Wedge Intercode Delay Examples

NOTE

If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.

STEP

ACTION

EXAMPLES

1

Desired Setting

No Delay

5 Seconds

60 Seconds

99 Seconds

2

Pad with leading zero(es)

00

05

60

99

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT INTERCODE DELAY SETTING

5

Scan Two Characters From

Appendix E, Keypad

‘0’ and ‘0’

‘0’ and ‘5’

‘6’ and ‘0’

‘9’ AND ‘9’

7

Scan ENTER/EXIT PROGRAMMING MODE