Ack character – Rice Lake Datalogic PowerScan PD7100 Series Laser Scanner User Manual

Page 66

Advertising
background image

RS-232/USB-Com Interfaces

58

PowerScan

®

PD7100 Corded

ACK Character

This setting specifies an ASCII character or hex value to be used as the ACK charac-
ter. ASCII characters or any hex value from 0 to 0xFF can be selected.

To set this feature:

1. Determine the desired character or value.

2. Use the

ASCII Chart

on the inside back cover of this manual to find the hex equiv-

alent for the desired character/value.

3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-

ming Mode.

4. Scan the barcode: SELECT ACK CHARACTER SETTING.

5. Scan the appropriate two alpha-numeric characters from the keypad in

Appendix

E, Keypad

, that represent the desired character/value in step

1

above. The second

character will cause a two-beep indication.

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-

ming Mode.

This completes the procedure. See

Table 8

for some examples of how to set this fea-

ture.

Table 8. ACK Character Setting Examples

NOTE

Setting to previously defined characters such as XON, XOFF, or host
commands conflicts with normal operation of these characters. 8-bit
data is not recognized when the option

Data Bits

has been set as 7

Data Bits.

STEP

ACTION

EXAMPLES

1

Desired Character/Value

ACK

$

@

>

2

Hex equivalent

0x06

0x24

0x40

0x3E

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT ACK CHARACTER SETTING

5

Scan Two Characters From

Appendix E, Keypad

‘0’ and ‘6’

‘2’ and ‘4’

‘4’ and ‘0’

‘3’ AND ‘E’

6

Scan ENTER/EXIT PROGRAMMING MODE