Code 128 set length 1, Code 128 — cont – Rice Lake Datalogic PowerScan PD7100 Series Laser Scanner User Manual

Page 193

Advertising
background image

Code 128

Product Reference Guide

185

Code 128 — cont.

Code 128 Set Length 1

This feature specifies one of the barcode lengths for

Code 128 Length Control

. Length

1 is the minimum label length if in

Variable Length

Mode, or the first fixed length if in

Fixed Length

Mode. Length includes the barcode’s data characters only.

The length can be set from 1 to 80 characters.

Follow these instructions to set this feature:

1. Determine the desired character length (from 1 to 80). Pad the number with lead-

ing zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.

2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-

ming Mode.

3. Scan the barcode: SELECT CODE 128 LENGTH 1 SETTING.

4. Scan the appropriate two digits from the keypad in

Appendix E, Keypad

, that rep-

resent the length setting which was determined in the steps above. You will hear a
two-beep indication after the last character.

5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-

ming Mode.

This completes the procedure. See

Table 23

for some examples of how to set this feature.

Table 23. Code 128 Length 1 Setting Examples

NOTE

If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.

STEP

ACTION

EXAMPLES

1

Desired Setting

01 Character

07 Characters

15 Characters

80 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT CODE 128 LENGTH 1 SETTING

4

Scan Two Characters From

Appendix E, Keypad

‘0’ and ‘1’

‘0’ and ‘7’

‘1’ and ‘5’

‘8’ AND ‘0’

5

Scan ENTER/EXIT PROGRAMMING MODE

Advertising