Chapter 3 - Printer Operation

29

Advanced Entry Calibration (continued)

Step

Action

Displayed Message

Comment

F

Use the UP and DOWN Arrow
buttons to set the Gain Number to
00.

Record the sensor reading as a
Label Value for Gain Number 00 in
a table (32 rows by four columns,
with headings similar to those
shown below.)

TRAN SENSOR GAIN

00

(0 - 31)

This is the Label Value for a gain
setting of 00.


Sample Calibration Table

Gain Number

Label Value

TOF Value

Difference Value

00 252

01

02

31



Step

Action

Displayed Message

Comment

G

Use the UP and DOWN Arrow
buttons to increment the Gain
Number by one and then Record
the Label Value.

Repeat this process for each Gain
Number.

TRAN SENSOR GAIN

01

(0 - 31)

This is the Label Value for a gain
setting of 01.


Sample Calibration Table

Gain Number

Label Value

TOF Value

Difference Value

00 252

01 250

02 248

… …

31 09